ENERGY & SOLAR · CALCULATOR
Calculate the Real Runtime of a Power Station
Enter your battery capacity, average load and overhead to see how long a power station could realistically keep your essential appliances running during a blackout.
Estimated runtime
13.1hours
at an average load of 65 W
- Usable energy
- 850 Whafter overhead losses
- Runtime if run 24 h/day
- 0.5 days
- Capacity needed for 24 h
- 1,835 Whplan the purchase, not just the runtime
Results recalculate as you type. Everything is a planning estimate.
A portable power station is sold with a big number on the front: its watt-hour capacity. That number is not what reaches your appliances. Inverting DC battery power into mains AC costs roughly ten to twenty percent. The battery manager reserves a slice at the top and bottom of every cycle. And the manual rarely tells you what is actually deliverable. That gap between advertised and usable capacity is where most blackout plans go wrong. It is usually discovered the hard way, at two in the morning, when the fridge stops.
This calculator converts the specification into the only figure that matters during an outage: hours of runtime. It takes the rated capacity, subtracts a realistic overhead for inversion and battery management, then divides by the average load you intend to run. The result is an estimate you can plan against. It tells you whether one station covers your fridge and router through a night outage. If not, you need a second unit, a larger model or a solar top-up.
The formula
Runtime (h) = Capacity (Wh) × (1 − overhead %) ÷ average load (W)
- Capacity (Wh)
- watt-hours stored in the battery, as stated by the manufacturer.
- overhead %
- share of energy lost to DC-AC inversion and battery management, typically 10–20% for AC loads.
- average load (W)
- mean power your devices draw over an hour, including duty cycles of cycling appliances.
- Runtime (h)
- estimated hours before the station reaches its low cut-off.
How the runtime formula works
The maths is deliberately simple because the inputs matter more than the algebra. Usable energy is the rated capacity times one minus the overhead fraction. Runtime falls out by dividing that usable energy by the average power drawn. A 1,000 Wh station with a 15% overhead delivers about 850 Wh; against a 65 W average load that is roughly thirteen hours. Change any one of the three inputs and the answer moves in proportion. The sensitivity is obvious. Halving your load doubles your runtime. A 20% overhead instead of 15% costs you about six percent of the total.
The overhead figure deserves a moment of thought. Running AC appliances through the built-in inverter is the expensive case - 10 to 20% lost as heat. Some devices charge over DC and skip inversion entirely. Think phones on the station's USB ports, or a 12 V fridge on the car-style socket. For an all-DC load you may drop the overhead to 5 to 10%. Conversely, a very light AC load can look worse than the maths suggests. The inverter's standby draw is a fixed cost, and it eats a larger share of a small budget.
- AC loads: assume 10–20% overhead (15% is a safe planning default)
- DC-only loads: 5–10% overhead is often achievable
- Very light loads: inverter standby draw can dominate the loss
Worked example: a 1,000 Wh station on fridge duty
Take a modern inverter fridge with a measured average draw of 65 W. That is not the 150 W nameplate. It is the true daily average logged by a meter - how fridges behave, with long idle stretches between short runs. Feed in 1,000 Wh of capacity, 65 W of load and 15% overhead. Usable energy is 850 Wh. Divide 850 by 65 and you get about 13.1 hours. Add a router at 15 W and the load becomes 80 W, pulling the estimate down to roughly 10.6 hours. That single arithmetic step - reusing the same formula for a different appliance set - is how you compare scenarios before buying anything.
Now flip the exercise. Suppose your target is surviving a nineteen-hour outage with the fridge and router running. You need 80 W × 19 h ÷ 0.85. That is about 1,790 Wh of rated capacity - a station nearly twice the size of the example unit. Asking for required capacity instead of available runtime is often the faster route to a buying choice. It is the same formula rearranged.
What counts as average load - and why nameplate watts mislead
The label on an appliance almost never tells you what it consumes over an hour. A kettle stamped 2,400 W only runs for a few minutes at a time. A fridge compressor rated 150 W may be active for a third of each hour, averaging nearer 50 to 80 W. A desktop PC idles at 40 W and spikes past 400 W under load. The number this tool wants is the time-averaged draw. The only honest way to get it is to measure with a plug-in energy meter over a full cycle. Or build the average from duty: rated watts times the fraction of the hour the device actually runs.
Where you cannot measure, work from typical averages rather than peaks. Plan on 40 to 80 W for a fridge, 10 to 20 W for a router, and 5 to 10 W per LED bulb. A laptop takes 50 to 90 W while charging. Surge matters too. Motor-driven appliances can draw three to seven times their running rating for a second or two. That barely changes your energy budget. It does decide whether the station's inverter can start the device at all. Check the continuous and surge ratings against the appliance before trusting any runtime figure.
Getting a more accurate estimate
Three refinements take this model from rough plan to dependable number. First, measure: a plug-in power meter costs little and logs real consumption, including the standby loads that quietly drain a small station overnight. Second, build a load profile. List every device, its average watts, and the hours per day you actually need it. Sum to a daily watt-hour budget and divide by your usable capacity. That day-based framing matches how outages are lived. Real outages mix heavy evening use with light overnight draws. A single continuous-hours figure fits that worse. Third, derate for age and temperature. Lithium cells lose capacity as they cycle. Cold garages or caravans can cut available capacity by a fifth or more until the cells warm.
It also helps to treat the result as a band rather than a point. If the tool says thirteen hours, plan around eleven to fifteen. The low end covers an older battery, a colder room and an inverter working hard. The high end assumes a fresh battery, a warm room and mostly DC charging. Plans that only work at the optimistic end of the band usually fail during the first real outage. The whole purpose of the estimate is to build in margin on purpose, not to discover it under pressure.
Accuracy, assumptions and limitations
This calculator models energy, not power. It assumes your load sits inside the station's continuous inverter rating. It assumes a healthy battery and constant overhead. Real inverters vary their efficiency with load, often worst at very low draw. It does not model battery degradation, deeply discharged cells, temperatures below freezing, or the manufacturer's hidden reserve that keeps the last few percent unreachable. None of those are flaws in the maths; they are simply reasons to keep a margin rather than plan down to the final watt-hour.
The companion assumption is behaviour: runtime figures only hold if you actually shed non-essential loads. A station that runs a fridge for thirteen hours will run for three if someone boils a kettle twice and charges a games console. Small extras eat the plan fast. Write the priority list into your plan before the outage, not during it, and the estimate becomes a commitment instead of a guess.
Reference values
Typical average draws for planning (measure yours where you can)
| Device | Average draw | Notes |
|---|---|---|
| Inverter-compressor fridge | 40–80 W | Duty-cycled average, not nameplate |
| Wi-Fi router + modem | 10–30 W | Near-continuous load |
| LED lighting string (3 bulbs) | 15–25 W | 5–10 W per equivalent bulb |
| Laptop charging | 50–90 W | Runs only while charging |
| CPAP (no humidifier) | 25–60 W | Check your model's measured draw |
| Television (mid-size LED) | 50–120 W | Larger and OLED screens draw more |
| Chest freezer | 100–150 W | Duty cycle rises in warm rooms |
| Electric kettle | 1,800–3,000 W | Minutes of use - often the station's rating limit |
Key terms
- Watt-hour (Wh)
- A unit of energy: one watt running for one hour. Battery capacity is quoted in Wh.
- Inverter overhead
- Energy lost converting the battery's DC output into mains AC, mostly as heat.
- Duty cycle
- The fraction of time a cycling appliance (fridge, pump) actually runs, which turns nameplate watts into an average draw.
- Depth of discharge
- How far a battery is drained per cycle; regularly discharging to empty shortens life, which is why stations cut off early.
- Surge rating
- Short-term peak power an inverter can deliver to start motor loads, above its continuous rating.
Tips and common mistakes
Field-tested tips
- Charge phones and cameras from the station's DC/USB ports rather than AC adapters - skipping inversion can recover most of that 15% loss.
- Measure the fridge for a full day with a plug-in meter before buying: average draws swing 40–150 W between models and rooms.
- Run two scenarios - essentials only, and essentials plus comfort loads - and size the battery against the second, not the first.
- Warm a cold battery before expecting full capacity; winter garage storage can hide a fifth of your runtime.
Common mistakes
- Using the nameplate watts on the appliance label instead of its measured average draw.
- Planning to the last estimated hour with no margin for battery age, cold or inverter standby losses.
- Ignoring surge: a station with enough energy but too small an inverter will still refuse to start a fridge or pump.
- Forgetting the kettle effect: one minute of boiling can consume more energy than an hour of lighting.
Frequently asked questions
Why can't I use the full advertised capacity?
Because three separate losses sit between the label and your appliance. The inverter converts DC to AC at roughly 85–90% efficiency. The battery manager reserves the top and bottom slices of every cycle to protect cell life. And standby electronics draw power even when nothing is plugged in. Together they explain why a 1,000 Wh station realistically delivers somewhere around 800–900 Wh to AC loads, and why the overhead input exists.
Does a fridge's starting surge change the runtime figure?
Barely - the surge lasts one or two seconds, so its share of total energy is tiny. Its real significance is power, not energy: the inverter must be rated to survive that momentary three-to-seven-times spike. Check the station's surge rating against the fridge's starting watts before trusting any runtime estimate. A station with enough energy but not enough instantaneous power will simply shut down when the compressor tries to start.
Can solar extend the runtime number?
Yes, and it changes the maths from a fixed battery to a flowing one. If your panel delivers more watts on average than your load consumes, capacity stops being the limit. You effectively run indefinitely while the sun holds up. The solar recharge calculator covers the panel side of that equation, including why rated panel watts rarely arrive as delivered watts.
How much do battery age and temperature matter?
More than most owners expect. Lithium cells lose a few percent of usable capacity every few hundred cycles. Cold slows the chemistry too. A station kept in a freezing garage or caravan can show far less available energy than the same unit in a warm kitchen. If your runtime estimate lands close to your outage need, derate another ten to fifteen percent for age and temperature before you sign off on the plan.
About this calculator
- Written by
- Spare Theory Editorial Team · Research & Testing Desk
- Last reviewed
- 2026-10-13
How we calculateFormulas use standard energy arithmetic; overhead ranges follow the 10–20% losses stated in manufacturer documentation and independent power-station reviews. Average-draw figures are typical published ranges, not measured claims about any specific product.
Reference basisManufacturer specification sheets and owner manuals for portable power stations · IEC 62619 - industrial lithium cell safety standards · Plug-in energy meter measurement methodology